Honda Accord

1998-1999 of release

Repair and car operation



Honda Chord
+ Honda Accord brand Cars
+ Settings and routine maintenance
+ Engine
+ Systems of cooling, heating
+ Power supply system and release
- Engine electric equipment
   General information and precautionary measures
   Engine start from the auxiliary power supply
   Check of a condition and battery replacement
   Check of a condition and replacement of wires of the battery
   Ignition system - the general information
   Check of functioning of system of ignition
   Check of a condition and replacement of the coil of ignition
   Check of serviceability of functioning and replacement of the module of management with ignition (ICM)
   Removal and installation of the distributor of ignition
   Check of installation of a corner of an advancing of ignition
   Charge system - the general information and precautionary measures
   Check of a condition of system of a charge
   Removal and generator installation
   Replacement of a regulator of tension and generator brushes
   Start system - the general information and precautionary measures
   Check of serviceability of functioning of a starter on the car (in situ)
   Removal and starter installation
   Removal and installation of the traction relay
+ Engine management
+ gear shifting Box
+ Coupling and power shafts
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment
+ electric equipment Schemes





Removal and generator installation

REMOVAL

 PERFORMANCE ORDER

1. Disconnect a negative wire from the battery.

If the stereosystem established on the car is equipped with a security code before disconnecting the battery make sure that have the correct combination for audiosystem input in action!

2. Previously having marked, disconnect from the generator electroconducting and grounding tires.
3. On 4-cylinder models weaken adjusting and axial bolts of the generator, then throw off a driving belt. Remark: On 4-cylinder models the adjusting bolt passes in the plane parallel to a driving belt and can be weakened only after a preliminary otpuskaniye of a lock-nut. The V6 models are equipped with a tape driving belt with an automatic regulator of the tension which procedure of removal is described in Head of Control and routine maintenance.

4. On the V6 models disconnect electroconducting from the To/in fan and take assembly of last of an impellent compartment (see. Head of System of cooling, heating).

5. On 4-cylinder models turn out adjusting and axial bolts and remove the generator from the engine. On the V6 models simply turn out fixing bolts of the top and bottom arms and take the generator from an impellent compartment. accurately bypassing plaits of electroconducting and hoses.

6. In case of need generator replacements, take the block removed from the car with itself in shop as an example - the replaceable generator should correspond on the technical characteristics failed. Compare plugs, - they should have the same numbering, the size and an arrangement. In summary, compare the identification marking which has been usually beaten out on the case of the block, or printed on the label tied up to it - identification numbers of old and replaceable generators should coincide.
7. Usually replaceable generators are delivered without a driving pulley which in that case is necessary for rearranging from the old block.
Installation
8. Installation is made upside-down.
9. In summary adjust a tension of a driving belt (see. Head of Control and routine maintenance).
10. For check of serviceability of functioning of the generator measure tension of a charge developed by it (see. Section Check of a condition of system of a charge).