   General information and precautionary measures
   Engine start from the auxiliary power supply
   Check of a condition and battery replacement
   Check of a condition and replacement of wires of the battery
   Ignition system - the general information
   Check of functioning of system of ignition
   Check of a condition and replacement of the coil of ignition
   Check of serviceability of functioning and replacement of the module of management with ignition (ICM)
   Removal and installation of the distributor of ignition
   Check of installation of a corner of an advancing of ignition
   Charge system - the general information and precautionary measures
   Check of a condition of system of a charge
   Removal and generator installation
   Replacement of a regulator of tension and generator brushes
   Start system - the general information and precautionary measures
   Check of serviceability of functioning of a starter on the car (in situ)
   Removal and starter installation
   Removal and installation of the traction relay
+ Engine management
+ gear shifting Box
+ Coupling and power shafts
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment
+ electric equipment Schemes





Charge system - the general information and precautionary measures

The generator of the alternating current which has been built in it a regulator of tension, control lamp of a charge, the storage battery, protective fusible insert and electroconducting connecting listed components belong to number of components of system of a charge. The system of a charge provides giving of an electric food to ignition system, lighting and alarm devices, a radio receiver and other consumers of the electric power. The generator is put in action by a belt drive from a pulley of a cranked shaft and is established in a forward part of the engine. Additional information on electric connections of components of system of a charge can be gathered from schemes of electric connections.

The electronic control unit (RSM), depending on the current values of input parameters (engine turns, speed of movement of the car, temperature of cooling liquid, number of the included consumers of the electric power and temperature of soaked-up air), makes adjustment of size of tension developed by the generator. The main task of system is minimization of load of the engine.

Problem of a regulator of tension is restriction of tension developed by the generator in the set limits. The regulator prevents overloads of contours and the other unpleasant phenomena connected with power surges.

The system of a charge does not need regular service. Nevertheless, it is necessary to check periodically a condition of a driving belt of the generator, the battery, connecting electroconducting and its terminal connections (see. Head of Control and routine maintenance).

The control lamp of a charge built in in an instrument guard quickly joins at ignition key turn in the situation ON. Right after implementation of start of the engine the lamp should go out. Refusal of a lamp of switching off testifies to malfunctions in charge system (see. Section Check of a condition of system of a charge).

On some models in an instrument guard the voltmeter allowing the driver in time to trace deviations of onboard tension from norm is in addition established. At an exit of indications of the voltmeter out of limits of an admissible range it is necessary to make check of system of a charge (see. Section Check of a condition of system of a charge).

The fusible insert represents the short piece of the wire placed in isolation which has been built in in the main plait of electroconducting of an impellent compartment. The total section of a vein of the conductor of an insert several times is less than at chain electroconducting in which it is included that guarantees reliable protection of the last against an overload.

Precautionary measures

When joining terminal connections of electric chains equipped with the generator of an alternating current of cars it is necessary to observe special precautionary measures:

a) At connection of electroconducting of the battery to the generator at all do not allow polarity violation;
b) Before applying at body repair electroarc welding disconnect electroconducting from plugs of the generator and the storage battery;
c) At all do not make engine start at the charger connected to the battery;
d) Always, before making a battery charging from the external power supply, disconnect from it both wires (at first negative);
e) Try not to allow hit of hands, hair and free parts of clothes in contact to a rotating driving belt of the generator during checks made at the working engine;
f) As the generator is connected directly to the battery, its overloads and short circuits are capable to cause ignition of electroconducting and to be at the bottom of a fire;
g) Before starting steam cleaning of an impellent compartment wrap the generator in a plastic bag which then should be fixed reliably rubber bandages.